{"id":7284,"date":"2026-06-12T16:30:03","date_gmt":"2026-06-12T08:30:03","guid":{"rendered":"https:\/\/hobertek.com\/?p=7284"},"modified":"2026-06-12T16:30:03","modified_gmt":"2026-06-12T08:30:03","slug":"7284-2","status":"publish","type":"post","link":"https:\/\/hobertek.com\/es\/7284-2\/","title":{"rendered":""},"content":{"rendered":"<h1>How to Choose the Right HOBER Solar Pump Inverter: A Complete Selection Guide<\/h1>\n<p>Choosing the right solar pump inverter for your deep well or surface pump is critical for system longevity and water output efficiency. At HOBER, with <strong>16 years of R&amp;D and manufacturing experience<\/strong>, we follow a core engineering principle: <strong>The inverter power must be greater than or equal to the pump power.<\/strong><\/p>\n<p>In most cases, we recommend selecting &quot;one size up&quot; to ensure maximum system stability. Here is our professional step-by-step guide to making the right choice.<\/p>\n<hr \/>\n<h2>1. Confirm Your Pump\u2019s Basic Parameters<\/h2>\n<p>Before selecting an inverter, check your pump\u2019s nameplate for these three key details:<\/p>\n<ul>\n<li><strong>Fuerza<\/strong>: Measured in Watts (W) or Kilowatts (kW).<\/li>\n<li><strong>Voltaje<\/strong>: Single-phase pumps are typically 220V\/240V; Three-phase pumps are typically 380V\/400V\/440V.<\/li>\n<li><strong>Fase<\/strong>: Is it Single-Phase or Three-Phase?<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/hobertek.com\/wp-content\/uploads\/2026\/05\/hober-solar-pumping-diagram.png\" alt=\"Hobertek Solar Pumping Diagram\" \/><br \/>\n<em>Figure 1: Understanding how the inverter integrates into the total pumping system.<\/em><\/p>\n<hr \/>\n<h2>2. Understanding HOBER Model Nomenclature<\/h2>\n<p>Our model numbers follow the rule: <strong>HSPH-XXXX-H\/L-B<\/strong><\/p>\n<ul>\n<li><strong>HSPH<\/strong>: Hybrid Solar Pump Inverter (Supports both Solar &amp; AC input).<\/li>\n<li><strong>XXXX<\/strong>: Power rating. Numbers without &quot;K&quot; are Watts (e.g., 2200 = 2200W); with &quot;K&quot; are Kilowatts (e.g., 11KH = 11kW).<\/li>\n<li><strong>H\/L<\/strong>: Voltage type. <strong>h<\/strong> for Three-Phase (380V+), <strong>L<\/strong> for Single-Phase (220V).<\/li>\n<li><strong>B (Optional)<\/strong>: Built-in <strong>Booster<\/strong>. Models with a &quot;B&quot; allow for 1:1 precise power matching without needing to &quot;oversize&quot; the inverter.<\/li>\n<\/ul>\n<hr \/>\n<h2>3. Core Selection Rules<\/h2>\n<p>According to HOBER expert engineering standards, selection should follow this logic:<\/p>\n<h3><strong>The Power Rule<\/strong><\/h3>\n<p>Your goal is to satisfy: $\\text{Pump Power} \\le \\text{Inverter Power} \\le 1.2 \\times \\text{Pump Power}$.<\/p>\n<ul>\n<li><strong>Standard Models<\/strong>: Choose the model that is the next size up from your pump power. For example, for a 4kW three-phase pump, choose the <strong>HSPH5500H<\/strong> (5.5kW).<\/li>\n<li><strong>Booster Models (&quot;B&quot;)<\/strong>: If the inverter includes a built-in booster, you can match the power exactly 1:1.<\/li>\n<\/ul>\n<h3><strong>Type Matching<\/strong><\/h3>\n<ul>\n<li><strong>Single-Phase Pump (220V)<\/strong>: Must use an <strong>L-type<\/strong> inverter (e.g., HSPH2200L).<\/li>\n<li><strong>Three-Phase Pump (380V+)<\/strong>: Must use an <strong>H-type<\/strong> inverter (e.g., HSPH3700H).<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/hobertek.com\/wp-content\/uploads\/2026\/04\/hober-solar-pumping-diagram.png\" alt=\"Hober Solar Pump Banner\" \/><br \/>\n<em>Hobertek inverters are designed to handle high starting torques of industrial pumps.<\/em><\/p>\n<hr \/>\n<h2>4. Considerations for Deep Well vs. Surface Pumps<\/h2>\n<p>While electrical power is the main driver, the application environment matters:<\/p>\n<h3><strong>Bombas para pozos profundos<\/strong><\/h3>\n<p>Deep wells have high head requirements and heavy starting loads. We strictly advise the <strong>&quot;One Size Up&quot;<\/strong> rule to ensure enough starting torque. <\/p>\n<ul>\n<li><strong>Consejo profesional<\/strong>: If your cable length exceeds 150 meters, we recommend adding an <strong>output reactor or filter<\/strong> at the inverter output to protect the motor insulation.<\/li>\n<\/ul>\n<h3><strong>Bombas de superficie<\/strong><\/h3>\n<p>For surface pumps (like horizontal or vertical multi-stage pumps), the MPPT mode is often best set to <strong>PID mode<\/strong> during commissioning for smoother operation.<\/p>\n<hr \/>\n<h2>5. Quick Selection Examples<\/h2>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Pump Parameters<\/th>\n<th style=\"text-align: left;\">Recommended Inverter<\/th>\n<th style=\"text-align: left;\">Logic<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>1000W Single-Phase (220V)<\/strong><\/td>\n<td style=\"text-align: left;\"><strong>HSPH1500L (1.5kW)<\/strong><\/td>\n<td style=\"text-align: left;\">Next available single-phase size above 1000W.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>2.2kW Three-Phase (380V)<\/strong><\/td>\n<td style=\"text-align: left;\"><strong>HSPH3700H (3.7kW)<\/strong><\/td>\n<td style=\"text-align: left;\">Next available three-phase size for stability.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>15kW Three-Phase (380V)<\/strong><\/td>\n<td style=\"text-align: left;\"><strong>HSPH18.5KH (18.5kW)<\/strong><\/td>\n<td style=\"text-align: left;\">Follows &quot;one size up&quot; for high-power stability.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>750W Single-Phase (220V)<\/strong><\/td>\n<td style=\"text-align: left;\"><strong>HSPH750LB (750W)<\/strong><\/td>\n<td style=\"text-align: left;\">Booster &quot;B&quot; allows for exact 1:1 matching.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<h2>6. Environmental and Solar Configuration<\/h2>\n<ul>\n<li><strong>Altitude<\/strong>: If your project is above 1000 meters, the thinner air reduces cooling efficiency. You <strong>must<\/strong> derate the inverter (select a significantly larger power rating).<\/li>\n<li><strong>Solar Array Sizing<\/strong>: To ensure the pump runs reliably even in weak light, your total solar panel power should be roughly <strong>1.5 times<\/strong> the pump power.<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/hobertek.com\/wp-content\/uploads\/2026\/04\/solar-pump-inverter-sizing-tool-1.png\" alt=\"Solar Pump Sizing Tool\" \/><br \/>\n<em>Don&#8217;t guess\u2014use our professional sizing tool for the perfect match.<\/em><\/p>\n<hr \/>\n<p><strong>Need help with your specific project?<\/strong><br \/>\nAs an ISO9001-certified manufacturer, HOBER provides free technical assessments and customized design solutions. <a href=\"https:\/\/hobertek.com\/es\/about\/\"><strong>Contact our engineering team today<\/strong><\/a> to get your customized <strong>Estimation Letter<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<p>C\u00f3mo elegir el inversor de bomba solar HOBER adecuado: una gu\u00eda de selecci\u00f3n completa. C\u00f3mo elegir el inversor de bomba solar adecuado para su bomba de pozo profundo o de superficie.<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_robots_primary_cat":"none","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","om_disable_all_campaigns":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"_joinchat":[],"footnotes":"","jetpack_post_was_ever_published":false},"categories":[1],"tags":[],"class_list":["post-7284","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/hobertek.com\/es\/wp-json\/wp\/v2\/posts\/7284","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hobertek.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/hobertek.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/hobertek.com\/es\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/hobertek.com\/es\/wp-json\/wp\/v2\/comments?post=7284"}],"version-history":[{"count":1,"href":"https:\/\/hobertek.com\/es\/wp-json\/wp\/v2\/posts\/7284\/revisions"}],"predecessor-version":[{"id":7287,"href":"https:\/\/hobertek.com\/es\/wp-json\/wp\/v2\/posts\/7284\/revisions\/7287"}],"wp:attachment":[{"href":"https:\/\/hobertek.com\/es\/wp-json\/wp\/v2\/media?parent=7284"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/hobertek.com\/es\/wp-json\/wp\/v2\/categories?post=7284"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/hobertek.com\/es\/wp-json\/wp\/v2\/tags?post=7284"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}