{"id":7323,"date":"2026-06-23T18:34:46","date_gmt":"2026-06-23T10:34:46","guid":{"rendered":"https:\/\/hobertek.com\/?p=7323"},"modified":"2026-06-23T20:51:19","modified_gmt":"2026-06-23T12:51:19","slug":"solar-pump-inverter-hsph-series-for-wholesale-projects","status":"publish","type":"post","link":"https:\/\/hobertek.com\/pt\/solar-pump-inverter-hsph-series-for-wholesale-projects\/","title":{"rendered":"Solar Pump Inverter (HSPH Series) for Wholesale &#038; Projects"},"content":{"rendered":"<p><!-- ===== GEO: TL;DR \/ Key Answer block (AI-citable summary) ===== --><\/p>\n<div class=\"key-answer\" style=\"border:1px solid #dbe4ee;border-radius:10px;margin-bottom:28px;overflow:hidden;box-shadow:0 1px 3px rgba(15,23,42,0.06);\">\n<div style=\"background:#1e3a8a;color:#fff;padding:10px 20px;font-weight:700;font-size:1.02em;letter-spacing:0.02em;\">\n    &#9889; Quick Answer\n  <\/div>\n<div style=\"background:#f8fafc;padding:18px 22px;\">\n<p style=\"margin:0 0 14px;color:#334155;\">The HOBER HSPH Series is an industrial-grade solar pump inverter range designed for AC pumps from 0.75kW to 500kW in off-grid agricultural and municipal applications.<\/p>\n<ul style=\"list-style:none;margin:0;padding:0;\">\n<li style=\"padding:8px 0;border-bottom:1px solid #eef2f7;\"><span style=\"color:#1e3a8a;font-weight:700;\">1. Compatibility<\/span> &mdash; HSPH-L for single-phase (220\/240V), HSPH-H for three-phase (380-440V) pumps.<\/li>\n<li style=\"padding:8px 0;border-bottom:1px solid #eef2f7;\"><span style=\"color:#1e3a8a;font-weight:700;\">2. Power Range<\/span> &mdash; 0.75kW up to 500kW; large power units (75kW+) utilize IP65-rated cabinets.<\/li>\n<li style=\"padding:8px 0;border-bottom:1px solid #eef2f7;\"><span style=\"color:#1e3a8a;font-weight:700;\">3. Efficiency<\/span> &mdash; Integrated MPPT with >99% tracking efficiency maximizes daily water output.<\/li>\n<li style=\"padding:8px 0;\"><span style=\"color:#1e3a8a;font-weight:700;\">4. Sizing Rule<\/span> &mdash; Inverter power must be &ge; pump power; recommended ratio is 1.0x to 1.2x pump power.<\/li>\n<\/ul>\n<div style=\"margin-top:14px;background:#eaf1fb;border-left:3px solid #1e3a8a;padding:10px 14px;border-radius:4px;font-size:0.92em;color:#475569;\">\n      <strong>Exemplo:<\/strong> For a 15kW three-phase pump, a 15kW or 18.5kW HSPH-H inverter is used with approximately 22.5kW of total PV power.\n    <\/div>\n<\/p><\/div>\n<\/div>\n<p>For distributors and solar EPCs, the reliability of a solar pumping project hinges on the core control unit: the <strong>inversor de bomba solar<\/strong>. In high-demand agricultural and municipal water supply applications, system downtime is not just a technical failure\u2014it represents lost ROI and increased maintenance overhead for the contractor. HOBER, a specialized factory with 16 years of expertise, delivers the HSPH Series to solve these challenges with industrial-grade engineering.<\/p>\n<p>As a leading China-based manufacturer, HOBER operates five automated production lines under ISO9001 quality management, ensuring that every <a href=\"https:\/\/hobertek.com\/pt\/hober-solar-pump-inverter\/\">inversor de bomba solar<\/a> meets the rigorous standards required for global distribution and large-scale tenders.<\/p>\n<hr\/>\n<h2>Scalable Architecture: From Small Farms to 500kW Industrial Plants<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Specification<\/th>\n<th>Observa\u00e7\u00e3o<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Faixa de pot\u00eancia<\/td>\n<td>0.75kW &#8211; 500kW<\/td>\n<td>Covers residential to industrial projects<\/td>\n<\/tr>\n<tr>\n<td>Input Voltage (L-Series)<\/td>\n<td>220V\/240V Single Phase<\/td>\n<td>Optimized for light commercial\/residential<\/td>\n<\/tr>\n<tr>\n<td>Input Voltage (H-Series)<\/td>\n<td>380V\/400V\/440V Three Phase<\/td>\n<td>For high-flow irrigation and deep extraction<\/td>\n<\/tr>\n<tr>\n<td>Protection Rating<\/td>\n<td>IP65 (Cabinets) \/ IP20 (Standard)<\/td>\n<td>Cabinets available for 75kW-500kW models<\/td>\n<\/tr>\n<tr>\n<td>Sizing Ratio<\/td>\n<td>Inverter &ge; Pump Power<\/td>\n<td>Optimal range 1.0x to 1.2x pump power<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The HSPH Series is designed with a wide power range to accommodate diverse project scales. Whether you are supplying a small village water system or a massive irrigation scheme, HOBER provides a pre-matched solution that eliminates the guesswork of controller selection.<\/p>\n<ul>\n<li><strong>HSPH-L Series:<\/strong> Optimized for single-phase 220V\/240V AC pumps, providing a cost-effective solution for residential or light commercial water transfer.<\/li>\n<li><strong>HSPH-H Series:<\/strong> Built for heavy-duty three-phase 380V\/400V\/440V pumps, supporting high-flow irrigation and deep-well extraction.<\/li>\n<li><strong>HSPH-B (Booster) Models:<\/strong> Integrated step-up functionality for low-voltage PV strings, reducing the number of panels required for the startup voltage.<\/li>\n<li><strong>Cabinet Systems:<\/strong> For high-capacity projects (75kW to 500kW), we offer specialized IP65-rated inverter cabinets designed for outdoor durability in harsh environments.<\/li>\n<\/ul>\n<p><em>HOBER HSPH Series solar pump inverters are engineered for 24\/7 performance in remote off-grid locations.<\/em><\/p>\n<hr\/>\n<h2>Built-in MPPT and Advanced Control Logic<\/h2>\n<p>Maximizing water output from limited solar irradiance is the primary goal of any <strong>inversor de bomba solar<\/strong>. The HSPH series features an advanced Maximum Power Point Tracking (MPPT) algorithm with 99% efficiency, ensuring the pump starts earlier in the morning and stops later in the evening.<\/p>\n<p>Beyond simple motor control, HOBER inverters integrate comprehensive protection features including dry-run protection via water level sensors, over-voltage protection, and short-circuit shielding. For EPCs, this means fewer field failures and zero-risk handovers to the end-user. For projects with long cable runs exceeding 100 meters, HOBER provides pre-matched AC reactors to suppress dv\/dt noise and protect motor insulation.<\/p>\n<hr\/>\n<h2>Technical Sizing Rules for High-Efficiency Pumping<\/h2>\n<p>Correct sizing is critical for system longevity. To help our partners reduce engineering risk, HOBER provides a free <a href=\"https:\/\/hobertek.com\/pt\/hober-solar-pump-sizing-inverter-selection-tool\/\">solar pump sizing inverter selection tool<\/a>. When selecting an inverter, follow these mandatory factory guidelines:<\/p>\n<ul>\n<li><strong>Power Ratio:<\/strong> The inverter power must always be greater than or equal to the pump power. We recommend keeping the inverter power below 1.2x the pump power for optimal thermal performance.<\/li>\n<li><strong>Voltage Matching:<\/strong> Match the pump phase and voltage to the specific series (L for single-phase, H for three-phase).<\/li>\n<li><strong>PV Configuration:<\/strong> Total PV power should ideally be 1.5x the pump power to cover system losses and irradiance variations.<\/li>\n<\/ul>\n<hr\/>\n<h2>Perguntas frequentes<\/h2>\n<h3>Can I use a single-phase inverter for a three-phase pump?<\/h3>\n<p>No. You must match the phase of the inverter to the pump motor. Use the HSPH-L series for single-phase 220\/240V pumps and the HSPH-H series for three-phase 380\/400\/440V pumps.<\/p>\n<h3>What is the &#8220;B&#8221; suffix in HOBER inverters?<\/h3>\n<p>The &#8220;B&#8221; suffix denotes a &#8220;Booster&#8221; model. These inverters include integrated step-up functionality, which allows the system to reach the required startup voltage with fewer PV panels connected in series.<\/p>\n<h3>How do I protect the motor when the cable is very long?<\/h3>\n<p>For cable runs exceeding 100 meters, HOBER recommends and provides pre-matched output AC reactors. These components suppress dv\/dt noise and voltage spikes to protect the motor insulation from premature degradation.<\/p>\n<hr\/>\n<h2>Fa\u00e7a parceria com o l\u00edder de mercado com 16 anos de experi\u00eancia no setor.<\/h2>\n<p>HOBER supports global wholesalers and project contractors with more than just hardware. We provide full technical documentation, CAD drawings for tenders, and localized after-sales support to ensure your business stays competitive in the solar market.<\/p>\n<ul>\n<li><strong>ISO9001 Certified:<\/strong> Factory-direct quality control and reliability.<\/li>\n<li><strong>Territory Protection:<\/strong> Exclusive support for regional distributors.<\/li>\n<li><strong>Complete Systems:<\/strong> We supply the pump, inverter, PV panels, and all mounting accessories in a single SKU.<\/li>\n<\/ul>\n<p><strong>Ready to upgrade your next irrigation tender?<\/strong><\/p>\n<p><a href=\"https:\/\/hobertek.com\/pt\/about\/\">Entre em contato com o suporte t\u00e9cnico da HOBER.<\/a> today to receive our 2026 catalog and wholesale distributor price list. Let our engineers help you size the perfect system for your project requirements.<\/p>\n<p><script type=\"application\/ld+json\">\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"Article\",\"headline\":\"HOBER HSPH Series Solar Pump Inverters\",\"author\":{\"@type\":\"Organization\",\"name\":\"HOBER\"},\"publisher\":{\"@type\":\"Organization\",\"name\":\"HOBER\",\"url\":\"https:\/\/hobertek.com\"},\"inLanguage\":\"en\"}\n<\/script><\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can I use a single-phase inverter for a three-phase pump?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. You must match the phase of the inverter to the pump motor. Use the HSPH-L series for single-phase 220\/240V pumps and the HSPH-H series for three-phase 380\/400\/440V pumps.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the \\\"B\\\" suffix in HOBER inverters?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The \\\"B\\\" suffix denotes a \\\"Booster\\\" model. These inverters include integrated step-up functionality, which allows the system to reach the required startup voltage with fewer PV panels connected in series.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How do I protect the motor when the cable is very long?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"For cable runs exceeding 100 meters, HOBER recommends and provides pre-matched output AC reactors. These components suppress dv\/dt noise and voltage spikes to protect the motor insulation from premature degradation.\"\n      }\n    }\n  ]\n}\n<\/script><\/p>","protected":false},"excerpt":{"rendered":"<p>HOBER HSPH solar pump inverters, 0.75kW-500kW, single &#038; three phase, built-in MPPT. 16-year ISO9001 factory. Request the 2026 wholesale catalog.<\/p>","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","om_disable_all_campaigns":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"_joinchat":[],"footnotes":"","jetpack_post_was_ever_published":false},"categories":[76],"tags":[120,118,119,117],"class_list":["post-7323","post","type-post","status-publish","format-standard","hentry","category-solar-pump-inverter","tag-distributor","tag-hsph","tag-mppt","tag-solar-pump-inverter"],"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/hobertek.com\/pt\/wp-json\/wp\/v2\/posts\/7323","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hobertek.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/hobertek.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/hobertek.com\/pt\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/hobertek.com\/pt\/wp-json\/wp\/v2\/comments?post=7323"}],"version-history":[{"count":2,"href":"https:\/\/hobertek.com\/pt\/wp-json\/wp\/v2\/posts\/7323\/revisions"}],"predecessor-version":[{"id":7365,"href":"https:\/\/hobertek.com\/pt\/wp-json\/wp\/v2\/posts\/7323\/revisions\/7365"}],"wp:attachment":[{"href":"https:\/\/hobertek.com\/pt\/wp-json\/wp\/v2\/media?parent=7323"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/hobertek.com\/pt\/wp-json\/wp\/v2\/categories?post=7323"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/hobertek.com\/pt\/wp-json\/wp\/v2\/tags?post=7323"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}